Quick Start 4-7
© 2004 Pyramid Solutions Inc. Publication PUB-AB7603-008
Step 6: Enabling the Autobaud Option
If it is desirable to have the BridgeWay automatically determine the network baud
rate, the Autobaud option must be enabled.
Highlight the BridgeWay module by right clicking with the cursor on its
icon.
Select the Device menu option and pull down menu, then select Proper-
ties. A parameter screen is displayed.
Click on Upload. The parameter values will be read from the device.
Put the cursor “Autobaud” parameter value. Click to highlight it and then
click again to get a menu. From this menu select “Enable” or “Disable” to
enable or disable the autobaud option respectively.
Click Download to send the mode change to the BridgeWay.
Click Close.
Note: Changes to the autobaud option configuration do not take effect until the
module has been power cycled.
Note: If the BridgeWay is the only master on the DeviceNet network, DO NOT
enable autobaud. Automatic baud detection requires there to be traffic on the net-
work, there is typically no traffic until the master establishes connections.